Series 1 Ploymer Housed Metal-oxide Surge Arrester Arrester type (10KA) Rated voltage MCOV (KV) Steep current Impulse 1/10ms lighting impulse 8/20ms Switching current impulse 30/60ms 2000ms rectangul
Fuse Cutout(10-36KV) No. rated voltage (kv) rated current (ka) breaking current (A) impulse voltage (BIL) power frequency with stand voltage leakage distance Weight (kg)
Suspension Insulator Suspension insulator We can provide all kinds of Porcelain insulator,such as Pin type,Post type,Disc type and all kinds of porcelain insulator use on
Polymer Housed Arrester with Different diameter sh Series 1 Polymer Housed Metal-Oxide Surge Arrester without gap,Voltage class 6-36kV, all ratings are available from 5kA to 10kA.Series 2 Polymer Hous
Polymer Arrester We can export the complete products and accessories. Our products have been exported to Asia, South America. Europe, and the USA.Our products are as
Suspension Composite Insulator Series These insulators belongs to the Series 1: Suspension Insulator: 12 220kV Main Technical Parameters Type Rated voltage(KV)Specified mechanical load(KN
Lightning Arresters (KEMA) We can supply lightning arresters, fuse cutouts, composite insulators, surge arresters, zinc oxide varistors, Disconnecting switches, MOV blocks, met
Composite Insulator Performance:1. Excellent electrical characteristics and high mechanical strength; 2. Good resistance to soiling and resistance to flashover; 3.Small
Type C Fuse Cutout We can supply fuse cutout form 11kV 36kV, both 100A and 200A, with porcelain insulator or polymeric insulator. We can also manufacture the products a
Metal Oxide Varistor As zinc oxide varistor has a good voltage-ampere (Non-linearity) characteristic, hence the zinc oxide varistor is a very important components applied
MOV disk As zinc oxide varistor has a good voltage-ampere (Non-linearity) characteristic, hence the zinc oxide varistor is a very important components applied
Zinc Oxide varistor As zinc oxide varistor has a good voltage-ampere (Non-linearity) characteristic, hence the zinc oxide varistor is a very important components applied
Porcelain housed zinc oxide surge arrester without These products belong to theSeries 3 0. 28 36KV porcelain housed zinc oxide surge arrester without gap.Our products all meet the standards of ISO9001
Station Class Surge Arrester 54 258kV Thesesurge arrestersbelong to the series4 Station Class Surge Arrester, 54 258kV. All products meet the standards of ISO9001 and KEMA Our range produ
Composite Insulator ANSI class DC Composite Insulator ANSI class DC MainTechnical Data: SpecificationUnitCatalogue NumberHDDS-1HDDS-2HDDS-3HDDS-4Voltage classkV15252835ANSI Class-DS15
Suspension Composite Insulators Main Technical Parameters These insulators belongs to the Series 1: Suspension Insulator: 12 220kV TypeRated voltage (kV)Specified mechanical load (k
Station Post Composite Insulator Station Post Composite Insulator main technical data: TypeRated voltage (kV)Rated Cantilever load(kN)Section length(mm)Min. arcing distance (mm)Light
Pin Type Composite Insulator These insulators belongs to the Series 3: Pin type insulator:15kV,24kV,33KV Main Technical Parameters SpecificationHDPIN-15HDPIN-24HDPIN-33Rated Volt
Silicon Rubber Insulators 15-35kV SML 70kN These products are also available with ball and socket end fittings e.g. ----------------------------------------------------------
Expulsion Fuse Cutout 15/27kV-125kV BIL (HDF-05) Technical datas: · Rated voltage: 15kV(15-27kV) · Rated current:100A / 200A · BIL(LIW):125kV · Creepage distance:320mm (
Fuse Cutout HDF-13 11-15KV The dropout fuse Cutout is mainly used to protect lines and transformers against short circuits and overload Technical specification: Rated voltage
Dropout Fuse Cutout 15/27kV-125kV BIL (HDF-06) Technical datas: · Rated voltage: 15kV(15-27kV) · Rated current:100A / 200A · BIL(LIW):125kV · Creepage distance:320mm (
Expulsion Fuse Cutout 27/36 kV-170kV BIL (HDF-10) Technical datas: · Rated voltage: 36 (27-36kV) · Rated current:100A / 200A · BIL(LIW):170kV · Creepage distance:660mm (2
Dropout Fuse Cutout 24/27 kV-150kV BIL (HDF-07) Technical datas: · Rated voltage: 24 (24-27kV) · Rated current:100A / 200A · BIL(LIW):150kV ·Creepage distance:440mm (17
Fuse Cutout 15-27kV 125kV BIL Main technical parametersC.No.Rate voltage kVRate current(A)Breaking current(A)Impulse voltage(BIL)Power frequency with standvoltageleakage distanceW
Fuse Cutout We can supply lightning arresters, fuse cutouts, composite insulators, surge arresters, zinc oxide varistors, Disconnecting switches, MOV blocks, met
station class surge arrester Main Technical Data TypeRated voltage (kV)MCOV (kV)Max 0.5μs discharge woltage (kV)1Max switching surge protective level At classifying current le
porcelain housed metal-oxide surge arrester
polymer housed metal-oxide surge arrester Main Technical Data Arrester type (10kA)Rated voltage (kV)MCOV (Kv)Max. residual voltage(kV)2000μs Rectangular current withstand (A)4/10μs High
Surge arrester